•  DE | EN
TOP

Induction Ring - Vibration Test Systems 140 kN

Induction ring vibration exciter with force 140 kN
Induction ring vibration exciter with force 140 kN

Induction ring shakers operate with an all-metal moving coil with a single winding, in which an alternating voltage is induced by surrounding static coils, thus setting the moving coil in motion. Cooling is provided by a combined water/air cooler. The external cooling unit also provides the lubricant for the hydrostatic bearings, which enable friction-free mounting of the vibration armature.

Advantages of induction ring shakers:

  • No power connection to the vibration armature necessary -> Less failure susceptibility
  • High mechanical strength of the moving coil -> Greatly reduced maintenance requirements
  • High acceleration values
  • High resonance frequency of the vibrating armature

Induction ring - Vibration Test System TV 69440/AIT-480-IRS-210

Rated force Sinepk/RandomRMS/Shockpk: 140000/130000/420000 N
Frequency range: 5 – 3000 Hz
Main resonance frequency: 2400 Hz
Max. displacement Sine/Random/Shock Pk-Pk: 63.5/63.5/76.2 mm
Max. acceleration Sine/Random: 200/180 g
Max. acceleration Shock (at payload): 3 ms: 300 g (35 kg)
6 ms: 100 g (230 kg)
11 ms: 100 g (80 kg)
Total mass of shaker: 5300 kg
Dimensions of shaker WxHxD: 1775 x 1451 x 1251 mm
Armature diameter: 480 mm
Max. power consumption amplifier incl. cooling unit/field power supply: 60/40 kVA
Data sheet TV 69440/AIT-480-IRS-210  

Data sheet TV 69440/AIT-480-IRS-210 (imperial units)

 

Induction ring - Vibration Test System TV 69440/AIT-480-IRS-315

Rated force Sinepk/RandomRMS/Shockpk: 140000/130000/420000 N
Frequency range: 5 – 3000 Hz
Main resonance frequency: 2400 Hz
Max. displacement Sine/Random/Shock Pk-Pk: 63.5/63.5/76.2 mm
Max. acceleration Sine/Random: 200/180 g
Max. acceleration Shock (at payload): 3 ms: 300 g (60 kg)
6 ms: 100 g (240 kg)
11 ms: 100 g (300 kg)
Total mass of shaker: 5300 kg
Dimensions of shaker WxHxD: 1775 x 1451 x 1251 mm
Armature diameter: 480 mm
Max. power consumption amplifier incl. cooling unit/field power supply: 285/40 kVA
Data sheet TV 69440/AIT-480-IRS-315  

Data sheet TV 69440/AIT-480-IRS-315 (imperial units)

 

Induction ring - Vibration Test System TV 69440/AIT-480-IRS-402

Rated force Sinepk/RandomRMS/Shockpk: 140000/130000/420000 N
Frequency range: 5 – 3000 Hz
Main resonance frequency: 2400 Hz
Max. displacement Sine/Random/Shock Pk-Pk: 63.5/63.5/76.2 mm
Max. acceleration Sine/Random: 200/180 g
Max. acceleration Shock (at payload): 3 ms: 300 g (95 kg)
6 ms: 100 g (240 kg)
11 ms: 100 g (350 kg)
Total mass of shaker: 5300 kg
Dimensions of shaker WxHxD: 1775 x 1451 x 1251 mm
Armature diameter: 480 mm
Max. power consumption amplifier incl. cooling unit/field power supply: 370/40 kVA
Data sheet TV 69440/AIT-480-IRS-402  

Data sheet TV 69440/AIT-480-IRS-402 (imperial units)