•  DE | EN
TOP

Cooling blowers

Cooling blowers are used for cooling the shakers. TIRA mainly offers side channel blowers that provide an above-average cooling performance in comparison with axial  blowers. The low-maintenance blowers can also be installed outdoors.

Login

User login

Enter your username and password here in order to log in on the website. When you are logged in new content will be available.

Forgot your password?

Hier können Sie sich registrieren. Sign up here.

TB 0080 (for shakers with a nominal force of 200 N)

Volume flow:80 m³/h
Air hose diameter:40 mm
Dimensions WxHxD:246 x 247 x 256 mm
Total mass:10 kg
Used in vibration test systems:TV 51120(-M/-C), TV 52120, TV 51125-IN

TB 0140 (for shakers with a nominal force of 400 N to 1000 N)

Volume flow:140 m³/h
Air hose diameter:50 mm
Dimensions WxHxD:286 x 302 x 292 mm
Total mass:16 kg
Used in vibration test systems:TV 51140(-M/-C/-IN), TV 51165-IN, TV 5220(-M), TV 54216

TB 0310 (for shakers with a nominal force of 2700 N to 4000 N)

Volume flow:315 m³/h
Air hose diameter:60 mm
Dimensions WxHxD:382 x 384 x 432 mm
Total mass:42 kg
Used in vibration test systems:TV 50350(-M), TV 55240(-LSS/-MLSS)

TB 9 FUK (for shakers with a nominal force of 8 kN)

Volume flow:1080 m³/h
Air hose diameter:140 mm
Dimensions WxHxD:505 x 598 x 464 mm
Total mass:60 kg
Used in vibration test systems:TV 56280(-LSS/-MLSS)

TB 120 FUK (for shakers with a nominal force of 11 kN to 15 kN)

Volume flow:1500 m³/h
Air hose diameter:140 mm
Dimensions WxHxD:487 x 637 x 487 mm
Total mass:61 kg
Used in vibration test systems:TV 51010(-LSS/-MLSS), TV 57315(-LSS/-MLSS)

TB 7/FUK/11 (for shakers with a nominal force of 22 kN to 35 kN)

Volume flow:1920 m³/h
Air hose diameter:150 mm
Dimensions WxHxD:625 x 775 x 602 mm
Total mass:113 kg
Used in vibration test systems:TV 59322, TV 59327, TV 59335

TB 7/FUK/20 (for shakers with a nominal force of 49 kN to 70 kN)

Volume flow:5820 m³/h
Air hose diameter:175 mm
Dimensions WxHxD:625 x 773 x 602 mm
Total mass:131 kg
Used in vibration test systems:TV 59349, TV 59355, TV 59370

Noise protection

An aerated sound-absorbing chamber is offered for installing the cooling blower in closed rooms. In addition to this, silencers for damping the blow-off noise are offered.

Acoustic enclosure

Blower

Acoustic enclosure

DesignationDesignationDimensions LxWxHMassNoise reduction*
TB 0080TB 0080-AE860 x 650 x 760 mm45 kg15-23 dB(A)
TB 0140TB 0140-AE860 x 650 x 760 mm45 kg15-23 dB(A)
TB 0310TB 0310-AE860 x 650 x 760 mm55 kg15-23 dB(A)
TB 9 FUKTB 9-AE1470 x 1250 x 1393 mm103 kg5-23 dB(A)
TB 120 FUKTB 120-AE1470 x 1250 x 1393 mm103 kg5-23 dB(A)
TB 7/FUKTB 7/FUK-AE1470 x 1250 x 1393 mm103 kg5-23 dB(A)

 *depending on frequency

Silencer

Blower

Silencer

DesignationDesignationDimensions LxDMassNoise reduction*
TB 0080TB 0080-SI310 x 65 mm0.2 kg5 dB(A)
TB 0140TB 0140-SI308 x 82 mm0.2 kg8 dB(A)
TB 0310TB 0310-SI308 x 82 mm0.58 kg6 dB(A)
TB 9 FUKTB 9-SI1012 x 150 mm1.2 kg3-6 dB(A)
TB 120 FUKTB 120-SI1100 x 160 mm1.2 kg3-6 dB(A)
TB 7/FUKTB 7/FUK-SI1120 x 280 mm9.2 kg9-15 dB(A)

 **depending on frequency


Air-Water-Heat exchanger

The newly by TIRA developed Air-Water-Heat exchanger WWT is used for cooling down the exhaust air of the vibration test system to room temperature. This allows the operation inside rooms without problems. The heat exchanger is additionally designed as a noise protection casing and therefore offers highly efficient silencing
performance.

Air-Water-Heat exchanger

Blower

Air-Water-Heat exchanger

DesignationDesignationDimensions LxWxHMassNoise reduction*
TB 7/FUKWWT1200x1500x2080 mm800 kg kg30 dB(A)

 *depending on frequency