Induction Ring - Vibration Test Systems 140 kN
Induction ring shakers operate with an all-metal moving coil with a single winding, in which an alternating voltage is induced by surrounding static coils, thus setting the moving coil in motion. Cooling is provided by a combined water/air cooler. The external cooling unit also provides the lubricant for the hydrostatic bearings, which enable friction-free mounting of the vibration armature.
Advantages of induction ring shakers:
- No power connection to the vibration armature necessary -> Less failure susceptibility
- High mechanical strength of the moving coil -> Greatly reduced maintenance requirements
- High acceleration values
- High resonance frequency of the vibrating armature
Induction ring - Vibration Test System TV 69414/AIT-480-IRS-315
Rated force Sinepk/RandomRMS/Shockpk: | 140000/130000/420000 N |
Frequency range: | 5 – 3000 Hz |
Main resonance frequency: | 2400 Hz |
Max. displacement Sine/Random/Shock Pk-Pk: | 63.5/63.5/76.2 mm |
Max. acceleration Sine/Random: | 200/180 g |
Max. acceleration Shock (at payload): | 3 ms: 300 g (95 kg) 6 ms: 100 g (240 kg) 11 ms: 100 g (350 kg) |
Total mass of shaker: | 5300 kg |
Dimensions of shaker WxHxD: | 1775 x 1451 x 1251 mm |
Armature diameter: | 480 mm |
Max. power consumption amplifier incl. cooling unit/field power supply: | 135/40 kVA |
Data sheet TV 69414/AIT-480-IRS-315 | |